Fire Exit Signs

16th July 2025

In this article

    Share this article

    Fire exit signage plays a critical role in protecting lives during emergencies in the UK. These signs guide individuals swiftly and safely to the nearest available exit when a fire breaks out or when the power fails. Whether in schools, hospitals, factories, or offices, well-placed signage ensures that evacuation is carried out in a calm and efficient manner.

    In the UK, displaying compliant fire exit signage is not just advisable, it is legally required. Under laws like the Regulatory Reform (Fire Safety) Order 2005, all non-domestic premises must provide clear and sufficient signage to aid in emergency evacuation. Failure to meet these legal obligations can result in heavy penalties, fines, or imprisonment, and places lives at unnecessary risk.

    Kingfisher, a trusted name in workplace safety, provides expert guidance, audits, and training services to ensure your signage complies with every applicable regulation. Our consultancy gives organisations the reassurance that they are fully protected and legally compliant.

    Understanding Fire Exit Sign Regulations in the UK

    The UK has a robust legal framework surrounding fire exit signage. The cornerstone of these regulations is the Regulatory Reform (Fire Safety) Order 2005, commonly referred to as RRO 2005. This legislation requires the “responsible person” in any non-domestic building to ensure that suitable fire safety measures, including signage, are in place to enable a safe and timely evacuation.

    Alongside the RRO, the Health and Safety (Safety Signs and Signals) Regulations 1996 provide a general code for all workplace signage. These regulations help ensure signs are used effectively to prevent confusion and enhance safety. Oversight and enforcement of these rules fall under the remit of the Health and Safety Executive (HSE), which has the authority to conduct inspections and take legal action against non-compliant organisations.

    To bring consistency to sign design and application, British and international standards also apply. BS 5499-4 provides practical guidance on how fire exit signs should be designed, positioned, and sized for optimal clarity. Meanwhile, BS EN ISO 7010 introduces a standardised system of symbols, such as the now-familiar ‘running man’ icon, which transcends language barriers and ensures quick recognition in emergencies. Moving from older text-based signs to modern, symbol-based designs significantly improves evacuation efficiency and safety.

    Types of Fire Exit Signs and Their Features

    Fire exit signs come in different formats, each suited to specific building layouts and risk profiles. One of the most common distinctions is between photoluminescent and electrical signs.

    Photoluminescent signs are designed to glow in the dark, having absorbed ambient light during normal operation. These signs are incredibly useful in the event of a power failure, as they remain visible even in complete darkness. Because they do not require wiring or electrical connections, they are cost-effective and simple to install, making them a popular choice for low-risk or supplementary areas.

    In contrast, electrical fire exit signs, including those powered by mains electricity and energy-efficient LEDs, offer greater visibility and are essential in large or complex premises. These signs are often integrated with a building’s emergency lighting system, ensuring they remain illuminated during a loss of power. In high-occupancy buildings or long corridors, electrical signs offer superior performance.

    Accessibility is another key consideration in fire signage. Inclusive evacuation strategies demand signage that supports people with disabilities. Tactile signs with braille and raised text assist visually impaired individuals in navigating escape routes. Some environments may also benefit from hybrid signs, which combine universal symbols, multi-language instructions, and tactile elements to accommodate a broader range of users, including international visitors and people with cognitive impairments.

    Where and How to Install Fire Exit Signs

    Proper placement of fire exit signs is essential to ensure visibility and guide building occupants along the correct escape route without hesitation. Signs must be installed at every key decision point throughout a building. These include intersections in corridors, staircases, changes in direction, and above every final exit door leading out of the premises. In high-risk zones such as basements or plant rooms, additional signs may be needed to compensate for low lighting or complex layouts.

    Positioning is crucial for visibility. UK standards require signs to be mounted at a minimum height of two metres from floor level to the base of the sign. This height allows for uninterrupted visibility above obstacles such as furniture or open doors. Care must also be taken to ensure signs are not blocked by wall-mounted objects or architectural features, and that they remain clearly visible from all relevant angles.

    Beyond physical placement, illumination is a core factor. Signs must be readable in both normal and emergency lighting conditions. BS 5266 specifies the photometric standards that apply to emergency lighting systems. These systems must maintain luminance contrast to ensure signs are legible in low-light situations and must be backed up by an independent power source. Whether using photoluminescent signage or electrically illuminated signs, the aim is to guarantee continuous guidance to occupants during any crisis.

    Maintenance and Compliance: What You Need to Know

    Fire exit signage must be maintained with the same rigour as any other critical safety system. Without regular inspections, signs may become damaged, obscured, or faded, compromising their visibility and legal compliance.

    Routine maintenance includes monthly visual inspections to check for dirt, damage, or obstruction. Signs should be cleaned regularly to ensure readability. If changes to the room layout or partitioning occur, checks must be made to confirm that signs are still effective and visible from all required angles.

    Emergency lighting systems, which often work in tandem with fire exit signs, also need structured maintenance. A brief monthly functional test helps verify that backup lighting activates correctly in the event of a power failure. Once a year, a full discharge test should be performed to simulate a blackout and measure how long the system remains operational. Any identified issues must be logged and corrected immediately.

    Documentation is a crucial part of compliance. Organisations must keep up-to-date logs of all inspections, test results, and remedial actions. These records not only prove adherence to safety laws but also support internal risk management processes. Assigning responsibility to a designated staff member, or outsourcing inspections to a third party like Kingfisher, can help ensure consistency and accountability.


    How Kingfisher Can Support Your Signage Compliance

    Kingfisher offers comprehensive support to ensure your fire signage meets all regulatory and practical requirements:

    • On-Site Audits: Our consultants conduct fire risk assessments and signage audits tailored to your site’s layout
    • Training: We deliver hands-on workshops covering legal standards, inspection routines, and emergency procedures
    • Consultancy: From new building designs to legacy upgrades, our bespoke consultancy helps you maintain continuous compliance

    Let Kingfisher take the pressure off your shoulders, so you can focus on running your business safely.


    Quick Reference: Fire Exit Sign Installation & Maintenance Checklist

    Correct installation and maintenance can make the difference between a smooth evacuation and a potentially dangerous delay. Always ensure signs are placed at all key escape route points, installed at the correct height, and kept clean and clearly lit. Conduct monthly visual checks, annual lighting tests, and keep thorough records of all inspections and changes. Above all, designate a responsible person or partner with a specialist like Kingfisher to manage ongoing compliance.

    Conclusion 

    Fire exit signage is not just a regulatory requirement; it is a foundational element of any effective fire safety plan. Ensuring that signs are clear, well-lit, and strategically placed can drastically improve response times in an emergency and reduce panic.

    With the right signs in place, backed by consistent maintenance and supported by professional advice, your organisation can create a safer environment for everyone on site.

    Do not leave fire signage to chance. Reach out to Kingfisher for expert consultation, risk assessments, and training to help you comply with the law and protect your people.

    What’s the penalty for non-compliant fire exit signage?
    Failing to provide compliant fire exit signage can lead to serious legal consequences under the Regulatory Reform (Fire Safety) Order 2005. This includes enforcement notices, fines, and in extreme cases, imprisonment.
    Are photoluminescent signs enough without lighting?
    Photoluminescent signs can be effective, particularly in low-risk environments, but they must be evaluated as part of a wider risk assessment. In many cases, regulations such as BS 5266 recommend supplementary emergency lighting to guarantee visibility.
    Who’s responsible for signage in leased buildings?
    The responsibility typically lies with the “responsible person,” which could be the employer, managing agent, or leaseholder. It is essential to clarify roles in lease agreements and ensure fire safety duties are understood and fulfilled.

    Ensure Your Fire Signage is Fully Compliant

    Reading about fire exit signage is the first step, now let us help you put it into action. At Kingfisher, we take the complexity out of compliance. From on-site signage audits and tailored consultancy to hands-on training for your team, we provide everything you need to stay safe, legal and fully prepared. Visit our website to explore how we can support your business with expert fire safety solutions that deliver real peace of mind.